Start a conversation

Industry and energy

Machines, energy and process water, watched as they run.

Sensors on the machines that matter, a controller to collect them, and IoTyX to show their condition, the energy they use and the water they draw and discharge.

In the field
Controllers, with sensors on the machines
On the screen
Machine health, energy and a digital twin
To start
A pilot on the machines that matter most

IoTyX for industry and energy. An illustration with sample data, not a screenshot.

In short

For a plant, Ilonnati puts sensors and a controller on the machines whose condition matters most: pumps, motors, compressors, kilns, crushers and conveyors. IoTyX shows their vibration, temperature, voltage and current as they run, sets energy use against what was produced, and checks process and discharge water against its limits. A digital twin of the plant lets engineers watch it remotely and try process changes before making them. Readings that point to a developing fault raise an alert, so a machine can be serviced on a plan.

Who it is for

  • Cement, steel and process plants
  • Pharmaceutical and chemical manufacturers
  • Power producers and large energy users
  • Mines and heavy industrial sites

Today, and with Ilonnati

The same jobs, side by side: as they are usually done today, and as they run with Ilonnati.

Today

  • Machines are checked on rounds, and faults are found when something stops.
  • Energy arrives as a monthly bill, not per machine or per unit produced.
  • Process and discharge water are sampled by hand.
  • Gas, noise and air quality are measured at a few points, now and then.

With Ilonnati

  • Vibration, temperature, voltage and current arrive continuously from each monitored machine.
  • Energy is shown by source and by machine, against what was produced.
  • Water quantity and quality are measured where they enter and leave the process.
  • Gas leaks, noise and air quality are measured across the site, with alerts on thresholds.

A day at the plant

6 steps on one platform. Each names the module it uses.

  1. 01

    Sensors on the machines

    Vibration, temperature and electrical readings from the monitored machines reach IoTyX through a controller on site.

    Equipment monitoring
  2. 02

    The plant as a digital twin

    Kilns, crushers and conveyors appear as a live replica, so the plant can be watched from anywhere.

    Digital twin of the plant
  3. 03

    A reading drifts

    A motor’s vibration rises above its usual pattern, and the maintenance team is alerted.

    Predictive maintenance
  4. 04

    Service on a plan

    The machine is inspected at a planned stop rather than after it fails, and its history is on record.

    Predictive maintenance
  5. 05

    Energy per unit

    Grid, solar and generator supply are set against output, to show energy per unit produced.

    Energy monitoring
  6. 06

    Water in and out

    Cooling, process and discharge water are measured and checked against the limits that apply.

    Process water and effluent

The modules

Start with the ones you need and add the rest later, on the same platform and the same hardware.

  • Equipment monitoring

    Vibration, temperature, voltage and current on pumps, motors, compressors and HVAC, in real time.

  • Predictive maintenance

    Readings that point to a developing fault are flagged, so a machine can be serviced on a plan.

  • Digital twin of the plant

    A live replica of kilns, crushers and conveyors, used to watch the plant remotely and to try process changes before making them.

  • Energy monitoring

    Grid, solar, wind and generator supply in one view, down to the low-tension panel, with use per machine and per unit produced.

  • Process water and effluent

    The quantity and quality of cooling, process and discharge water, checked against the limits that apply.

  • Site safety

    Gas leaks, noise, air quality and worker exposure measured across the site.

  • Vehicles and site assets

    Where each vehicle is, its fuel use and performance, and each asset placed on a map of the site.

In IoTyX

What the hardware measures

Readings arrive in IoTyX as they are taken: on the web, on a phone and on the control room wall.

  • Vibration and temperature
  • Voltage, current and power
  • Gas flow and consumption
  • Process and cooling water
  • Effluent quality
  • Vehicle location and fuel use

Before you start

What is worth knowing before a project begins.

  • A pilot can start with the few machines whose failure costs the most, and grow from there.
  • If the plant already has a control system, bring its documentation to the first conversation, so the pilot works alongside it.
  • Whether IoTyX only watches a machine or also switches it is decided per project.

Questions buyers ask

Not answered here?

Ask about your own network, plant or campus. An engineer will reply.

Start a conversation
01Which machines can be monitored?

Pumps, motors, compressors and HVAC, and process equipment such as kilns, crushers and conveyors.

02What does the digital twin do?

It mirrors the plant’s equipment and processes in real time, so engineers can watch the plant remotely, see where readings are drifting, and try process changes virtually before making them.

03Can it show energy per unit produced?

Yes. Energy is measured per machine and by source, and set against production to give energy per unit.

04Does it replace our plant control system?

It is designed around what the plant already runs. What IoTyX watches, and what it is allowed to switch, is agreed for each project.

05Who can see and operate what?

Access is set by role. Administrators, engineers and operators each see the sites and zones they are responsible for, and only authorised people can send commands. Assets can also be shared with a contractor or partner.

06How does a project start?

With a conversation about the sites involved, then a demonstration or a pilot on part of the network or site. It is extended to the rest once the pilot has done what it was meant to.

Start a conversation

Tell us what you need to connect, monitor or control