Case study, Telangana
Remote valve control in a city water network
Ilonnati fitted remote valve control to existing valves in an urban water distribution network. Operators see the state of each connected valve and open, close or schedule it from the control room, where before each change meant sending a crew.
- Client
- A city water utility
- Sector
- Water utilities, government
- Solution
- Water and utilities
IoTyX for a water network. An illustration with sample data, not a screenshot of this deployment.
Before and after
The same work, as it was done before and as it runs now.
Before
- Valves were opened and closed by hand, by crews travelling to each one.
- There was no live view of which valves were open.
After
- Operators open, close and schedule a connected valve without a site visit.
- The state of each connected valve shows in the control room.
What Ilonnati delivered
Hardware in the field and the platform to run it, from one company.
Actuators on existing valves
Motorised actuators fitted to the valves in place, with no change to the pipes.
A controller at each valve
Each valve linked to the platform through an Ilonnati controller.
Live valve status
The position of every connected valve visible to operators as it changes.
Control room
Valves opened, closed and scheduled from the control room.
How each valve was fitted
An actuator on the existing valve, wired to a controller beside it. Red marks what Ilonnati fits; the rest was already there.
| No. | Part | What it does |
|---|---|---|
| Already in place | ||
| 1 | Pipe | Stays as it is: no change to the pipes. |
| 2 | Flanged joint | The valve’s joint to the pipe, left untouched. |
| 3 | Valve body | The valve already in the network. |
| 4 | Stem | Opens and closes the valve, now turned by the actuator. |
| Fitted by Ilonnati | ||
| 5 | Mounting bracket | Holds the actuator on the valve. |
| 6 | Coupling | Joins the actuator to the stem. |
| 7 | Motorised actuator | Opens and closes the valve remotely, on command or on a schedule. |
| 8 | Cable | Connects the actuator to the controller. |
| 9 | Ilonnati controller | Links the valve to IoTyX, where its state is shown. |
Questions buyers ask
Ask about your own network, plant or campus. An engineer will reply.
Start a conversation01Do the pipes or valves have to be replaced?
No pipe is replaced. Where a valve is in working order, a motorised actuator is fitted to it and a controller is placed beside it.
02Can operators work from a phone?
Yes. The IoTyX mobile app shows the network and lets authorised operators open or close valves and start pumps. Each command is confirmed before it is sent, and logged.
03What happens if a site loses its connection?
The controller keeps its readings while the connection is down and sends them when it returns.
04Who can see and operate what?
Access is set by role. Administrators, engineers and operators each see the sites and zones they are responsible for, and only authorised people can send commands. Assets can also be shared with a contractor or partner.